Sonatest Prisma Flaw Detector

$5.000

In Stock
  • Manufacturer: Sonatest
  • Model: Prisma Flaw Detector
  • Included: Dual UT Channels with: A-Scan recording, 2 Axis Encoding, Interface Triggering (IFT); 16:16, manual PA., A,B & C Scan Displays, USB Stick (8GB), Couplant, User Manual, 2 point neck harness, Lithium Ion Battery Packs (x2), External battery charger, Power cord & supply adaptor, Screen Protector, Transport Case (Airplane Carry on size)
Compare
Description

Sonatest Prisma Flaw Detector offers the end user, outstanding performance in the field together with the flexibility and capability to step up from using a high-end ultrasonic flaw detector to an instrument with phased array functionality.

Sonatest Prisma Flaw Detector provides the user with an ultrasonic Phased Array flaw detector. Sonatest Prisma Flaw Detector tool contains PA capability from 16:16 manual to 16:64, with 2D encoding.

Sonatest Prisma Flaw Detector an updated imaging system that allows the A scan, B scans and C scans to be used. The 3D ScanPlan includes the part, weld, wedge, probe and scan coverage. Sonatest Prisma Flaw Detectorcan be used in different areas of applications, such as aerospace, marine, composite and corrosion applications. In addition, the Prisma Phased Array equipment comes with numerous palettes for all scans.

 

Sonatest Prisma Flaw Detector Features:

  • Great PA capability from 16:16 manual through to 16:64 with 2D encoding.
  • UT to PA – and back
  • Enhanced Imaging Capability enables A-Scan, B Scans and C-Scans.
  • Advanced display modes include smoothing, contouring, averaging, envelope
  • A-Scan resolution  – up to 8192 points
  • New Configuration Wizard helps the technican to get the best out of the Prisma
  • TOFD is on board – so need to have extra instrumentation for TOFD Inspection.

 

Sonatest Prisma Flaw Detector Included:

  • Dual UT Channels with: A-Scan recording, 2 Axis Encoding, Interface Triggering (IFT)
  • 16:16, manual PA.
  • A,B & C Scan Displays
  • USB Stick (8GB)
  • Couplant
  • User Manual
  • 2 point neck harness
  • Lithium Ion Battery Packs (x2)
  • External battery charger
  • Power cord & supply adaptor
  • Screen Protector
  • Transport Case (Airplane Carry on size)

 

You may also be interested in Sonatest Masterscan 700M Flaw Detector

 

Sonatest Prisma Flaw Detector Specifications:

Conventional UTPhased Array
Pulsers
Configuration2 UT Channels16:16 or 16:64
Test ModePulse-Echo, Transmit/Receive and TOFDPulse-Echo, Transmit/Receive
Transducer SocketLEMO 1 or BNCI-PEX
Pulse Voltage-100V to -450V (in steps of 10V)-25V to -75V (in steps of 5 V)
PRF1Hz to 1500Hz1Hz to 5000Hz
Pulse ShapeNegative Square Wave (with ActiveEdge)Negative Square Wave (with ActiveEdge)
Pulse WidthAdjustable: Spike to 2000ns (2.5ns resolution)Adjustable: Spike to 1000ns (2.5ns resolution)
Edge Time15ns in 50Ω load @200V12ns in 50Ω load @50V
Output Impedance<10Ω
Trigger SynchronisationOn encoder resolution or internal PRF (both encoded or not)On encoder resolution or internal PRF (not encoded)
Focus Delay Rangen/a0 to 10μs (2.5ns resolution)
Damping ResistorSelectable: 50Ω or 400Ωn/a
Receivers
Gain Range100dB (0.1dB steps) Analogue Gain0 to 76 dB (0.1 dB steps), Analogue Gain
Max Input Voltage25Vp-p200mVp-p
Input Impedance1kΩ (pitch and catch)200Ω
Bandwidth200kHz to 22MHz (-3dB)200kHz to 14MHz
Analog Filters4 (automatic or manual)3 (automatic)
Digital Filters10 (automatic or manual)10 (automatic or manual)
RectificationFull wave, positive, negative, none (RF)Full wave, positive, negative, none (RF)
Signal EnhancementDigital filters, Smoothing, Contouring, Rejection, AveragingDigital filters, Smoothing, Contouring, Rejection
Focus Delay Rangen/a0 to 10μs (16ns resolution interpolated to 3.8ns)
Data Acquisition
Architecture2 channels, true 200MHz sampling rate16 Channels, Full digital Delay & Sum
Digitizer Resolution12bit ADC12bit ADC
Amplitude Measurement[0% to 100%] or [0% to 150%] FSH[0% to 100%] or [0% to 150%] FSH
Data Processing16bits/sample16bits/sample
Data RecordingFull raw data recording (plus sub-sampling options)Full raw data recording (plus sub-sampling options)
File Sizeup to 3GBup to 3GB
Digitizing Frequency50MHz, 100MHz, 200MHz65MHz
Focal Lawsn/a128
Focusing Moden/aNatural or constant depth/path/offset
Max A-Scan Length8192 samples4096 samples
Sub-Sampling1:1 to 1:1281:1 to 1:128
ReferenceInitial Pulse or Gate/IFT supportedInitial Pulse or Gate/IFT supported
Trigger Sync.Encoder or InternalEncoder or Internal
Scan & Views
Supported ScansA-Scan & TOFDS-Scan or L-Scan
Number of Scansup to 21 (with up to 3 extracted A-Scans)
ViewsA, B, C-Scan, Merged & TOFDA, B, C, L, S-Scan, Merged plus true TOP & END
Colour Mapsup to 10up to 10
Number of Layouts1835
Additional information
Weight10 kg
Dimensions60 × 60 × 50 cm
color

Gray

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Sonatest Prisma Flaw Detector”

Your email address will not be published. Required fields are marked *

Scroll To Top
Close
Close

Shopping Cart

Close

Shopping cart is empty!

Continue Shopping