Bruker TRACER 5 XRF Spectrometer is a handheld, portable spectrometer ideal for elemental analysis in the field and in laboratory-like settings.
Bruker TRACER 5 XRF Spectrometer specifically designed for methods development, research and complex material analysis, the TRACER 5g detects elements from Fluorine to Uranium (with a He atmosphere) and analyzes elements from Sodium to Uranium.
Bruker TRACER 5 XRF Spectrometer 5 has the ability to completely control the current and voltage. It also adds many new features which have been requested by our users. The user can select filters from the integrated filter wheel or insert user-designed filters. In addition, the measurements can be made in air, vacuum or helium atmosphere, which can be selected based on the needs of the user.
The detector configuration and a small distance between the sample and detector make for a very sensitive system with some of the lowest detection limits available today. Bruker TRACER 5 XRF Spectrometer has approximately three times the sensitivity of the previous generation TRACERs, with helium purge Bruker TRACER 5 XRF Spectrometer is the only handheld XRF that can elements as light as fluorine.
Bruker TRACER 5 XRF Spectrometer Features:
- 50kV-4W Rh target X-ray source
- Large area graphene window SDD detector
- Selectable measurement spot size 3 mm or 8 mm
- Helium purge and optional portable vacuum pump
- 5 position automatic filter changer
- Manual filter / secondary target option
- Integrated processor and data storage
- Interactive touch screen display
- Internal sample camera
- Wi-Fi and USB connectivity
- EasyCal software package for empricial user calibration
Bruker TRACER 5 XRF Spectrometer Included:
- Desktop Stand Kit
- Benchtop Stand Kit
- Prolene Windows
- Sample Preparation Cups
- Tripod kit
- Vacuum Pump
- Helium Assembly
- Carrying case
You may also be interested in Hilti PS 1000B X Scan Concrete Scanner
Bruker TRACER 5 XRF Spectrometer Specifications:
Excitation source | 50kV, 4W, Rh targetOperator adjustable current and voltage for optimum excitation. |
Detection | Large active area 20mm2 SDD detector with graphene window<140eV @ 250,000 cps Mn Ka resulution. |
Collimation | User changeable collimator; 3 mm and 8 mm collimators supplied.Internal sample camera to identify exact measurement position. |
Filters | Operator controlled, 5 position primary beam filter wheel.Manual filter/secondary target slot for factory or user made filters. |
Size and weight | Weight: 1.9 kg with batterySize (LxWxH): 27 cm x 9 cm x 30 cm |
Elemental Range | Sodium to Uranium (air and vacuum)Fluorine to Uranium (with helium purge) |