Olympus 37DL Plus Ultrasonic Thickness Gauge is an advanced nondestructive ultrasonic thickness gage that combines powerful measurement features with sophisticated data acquisition and output capabilities for applications involving pipes, tanks, and other metal structures subject to internal corrosion or erosion.
Olympus 37DL Plus Ultrasonic Thickness Gauge includes many innovative features that simplify true metal thickness measurements even when the exposed surface is coated or painted. The patented Thru-Coat technology measures and displays the thickness of the metal part and its coating using a ‘single backwall echo’. A Oxide/ Scale option measures and displays the thickness of the steel and the oxide/scale build-up on the inside of boiler tubes to help predict tube life.
Olympus 37DL Plus Ultrasonic Thickness Gauge Accuracy of high temperature thickness measurements can be improved by using the Temperature Compensation feature that adjusts the material velocity for changes in material temperature. A new Average/Min mode saves the average or minimum of several successive thickness measurements.
Olympus 37DL Plus Ultrasonic Thickness Gauge can be used with a vast selection of dual element and single element transducers. Its full line of D790 series dual element transducers feature Automatic Probe Recognition to provide maximum gage performance for each transducer.
Olympus 37DL Plus Ultrasonic Thickness Gauge Features:
- Patented Thru-Coat™ technology measures and displays the thickness of the metal part and its coating using a ‘single backwall echo’.
- Temperature Compensation feature adjusts the material velocity for changes in material temperature.
- Optional Oxide/Scale feature measures and displays the thickness of the steel and the oxide/scale build-up.
- Average/Min mode saves the average or minimum of several successive thickness measurements.
- A-scan display is brighter with better contrast and visibility.
- Uses a vast selection of dual element and single element contact, delay line, and immersion transducers.
- EMAT transducers for no-couplant steel thickness measurements through heavily scaled surfaces.
- The file-based alphanumeric datalogger can use longer file names (32 character max) and ID numbers (20 character max).
- Every thickness reading in a stored B-scan can now be reviewed in the GageView Interface Program and on the gage.
- Select to view (Min/Max, Alarm, or Ascan flags) flags for Grid points.
- Grid files can be expanded by adding rows or columns or by changing the incrementing direction.
Olympus 37DL Plus Ultrasonic Thickness Gauge Included:
- Panametrics 37DL Plus Ultrasonic Corrosion Thickness Gage (BC# 41506-L/T*)
- Panametrics Thickness Probe
- AC Adapter/Charger
- Power Cord Carrying Case (G)
You may also be interested in Olympus 38DL PLUS Ultrasonic Thickness Gauge
Olympus 37DL Plus Ultrasonic Thickness Gauge Specifications:
Dual Element Measurement Mode: Time interval from a precision delay after the excitation pulse to the first echo. | |
Thru-Coat Measurement: Measurement of true metal and coating thickness using a single backwall echo (with D7906-SM and D7908 transducers). | |
Thru-Paint Echo-to-Echo: Time interval between two successive backwall echoes for elimination of paint or coating . | |
Single Element Measurement Mode: | Mode 1: Time interval between excitation pulse to first backwall echo. |
Mode 2: Time interval between delay line echo to first backwall echo with delay or immersion transducers. | |
Mode 3: Time interval between successive backwall echoes following the first interface echo after the excitation pulse with delay line or immersion transducers. | |
Optional Oxide/Scale Measurement: Measure metal thickness and internal oxide/scale build-up of pipes. Oxide/scale thickness range: M2017: 0.010 – 0.050” (0.25 – 1.25 mm) M2091: 0.006 – 0.050” (0.15 – 1.25 mm) | |
Thickness Range: 0.003 – 25.000 inches (0.080 – 635.00mm), depending on material, transducer surface condition, temperature, and SETUP selected | |
Material Velocity Range: 0.020 – 0.551 inch/μS (0.508 – 13.998 mm/μS) | |
Resolution, selectable: | LOW: 0.01” 0.1 mm |
STANDARD: 0.001” 0.01 mm | |
Transducer Frequency Range: | 2-30 MHz (-3 dB) |
Operating Temperature: | -10 to +50°C (+14° to 122°F) |
Keypad: | Sealed color-coded keypad with tactile and audible feedback |
Case: | Impact-resistant and Water-resistant, gasketed Lexan® case with sealed connectors. Environmental IP-65 compliant |
Liquid Crystal Display: | With backlight. Contrast keypad adjustable. Display area 4.0 x 3.39 inch (102 x 86 mm) |
Hazardous Area Operations: | As defined by MIL-STD-810E, method 511.3, procedure 1 |
Rectification: | Full wave, RF, half wave positive, or half wave negative |
Reviews